Leave Your Message

Replacement Guide for Four Filters & Two Oils of Deman Screw Air Compressors

2026-07-20

Regular maintenance of screw air compressors centers on timely replacement of the four filters and two oils. Deman’s 10-year full machine warranty is premised on standardized maintenance. Taking Deman screw air compressors as an example, this article details replacement procedures and service cycles for the four filters and two oils to standardize daily maintenance.

Replacement Procedures for Four Filters

  1. Pre-filter Dust Sponge

Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first

Operation Steps:

Pull out the dust sponge from the side cabinet of the compressor

Blow dust off the sponge from inside out with compressed air; replace the sponge directly if it is damaged or heavily clogged

  1. Air Filter Element

Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; shorten the cycle under harsh working conditions; replace immediately once the differential pressure transmitter triggers an alarm

Operation Steps:

Loosen the locking ring screw

Take out the old air filter element

Blow the filter element from inside out with compressed air for reuse, or install a brand-new filter directly

  1. Oil Filter

Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; shorten the cycle under harsh working conditions; replace immediately once the differential pressure transmitter triggers an alarm

Operation Steps:

Clamp the oil filter with a chain wrench

Rotate counterclockwise to remove the old oil filter

Apply a thin layer of lubricant to the sealing ring of the new oil filter; hand-tighten first, then turn another 1/2~3/4 turn with the chain wrench (avoid over-tightening to prevent sealing ring damage)

  1. Oil-Air Separator Element

Two types of oil separator elements are available: built-in and external. Confirm the type before replacement.

Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; shorten the cycle under harsh working conditions; replace immediately once the differential pressure transmitter alarms; inspect or replace early if excessive oil consumption is observed

(1) External Oil Separator Element

Replacement steps are identical to the oil filter: unscrew the old separator element with a chain wrench and install the new one.

(2) Built-in Oil Separator Element

Remove all screws around the top cover of the oil tank

Unscrew the bolts of the minimum pressure valve

Disconnect all connected thin pipelines

Pry gently from the side with a flat screwdriver and take out the old oil separator element

Install the new separator element, then reassemble all components in reverse order of disassembly

四滤二油3.jpg  四滤二油 1.png

Replacement Procedures for Two Oils

  1. Deman Special Compressor Lubricating Oil

Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; check oil level regularly; top up oil if the level falls below the standard mark under rated operating frequency

Operation Steps:

Oil Drain: Unscrew the hex bolt at the end of the ball valve, connect an oil drain hose, and drain all old oil into a dedicated waste oil barrel. After full drainage, jog the main airend for 2~3 seconds to discharge residual oil.

Oil Refill: Unscrew the oil filler cap, pour in new Deman special screw compressor oil until the liquid level reaches the upper red line of the oil sight glass.

Verification: Ensure the running oil level stays between the two red lines on the sight glass during unit operation.

Warning: Never mix lubricants of different brands or models. Only Deman designated special oil can be used; mixing oil may cause coking, carbon buildup, or even main airend seizure.

  1. Motor Bearing Grease

Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; adjust the cycle earlier or later based on actual operating conditions

Special Notes:

Sealed motor bearings require no grease refilling

Bearings must be replaced every 20,000 operating hours

Operation Steps:

Unscrew the grease nipple on the motor

Inject new bearing grease with a grease gun

Do not overfill grease, as excessive grease will lead to bearing overheating

Maintenance Cycle Schedule

Maintenance Item

Recommended Cycle

Key Replacement Notes

Dust Sponge

4,000 hrs / 1 year

Blow clean or replace

Air Filter Element

4,000 hrs / 1 year

Blow dust from inside out before reuse

Oil Filter

4,000 hrs / 1 year

Lubricate sealing ring during installation

Oil-Air Separator Element

4,000 hrs / 1 year

Distinguish built-in / external structure

Special Compressor Lubricating Oil

4,000 hrs / 1 year

Use designated oil only; no mixing

Motor Bearing Grease

4,000 hrs / 1 year

No refilling for sealed bearings; replace bearings at 20,000 hrs

Safety Reminder: Shut down the unit completely before maintenance, fully release system pressure, disconnect the main power supply, and hang a "Do Not Close Switch" warning sign. After maintenance, verify all parts are correctly installed before trial startup.

Deman's nationwide after-sales team provides professional maintenance and repair services. If you need on-site service or technical guidance, please contact us.