Replacement Guide for Four Filters & Two Oils of Deman Screw Air Compressors
Regular maintenance of screw air compressors centers on timely replacement of the four filters and two oils. Deman’s 10-year full machine warranty is premised on standardized maintenance. Taking Deman screw air compressors as an example, this article details replacement procedures and service cycles for the four filters and two oils to standardize daily maintenance.
Replacement Procedures for Four Filters
- Pre-filter Dust Sponge
Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first
Operation Steps:
Pull out the dust sponge from the side cabinet of the compressor
Blow dust off the sponge from inside out with compressed air; replace the sponge directly if it is damaged or heavily clogged
- Air Filter Element
Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; shorten the cycle under harsh working conditions; replace immediately once the differential pressure transmitter triggers an alarm
Operation Steps:
Loosen the locking ring screw
Take out the old air filter element
Blow the filter element from inside out with compressed air for reuse, or install a brand-new filter directly
- Oil Filter
Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; shorten the cycle under harsh working conditions; replace immediately once the differential pressure transmitter triggers an alarm
Operation Steps:
Clamp the oil filter with a chain wrench
Rotate counterclockwise to remove the old oil filter
Apply a thin layer of lubricant to the sealing ring of the new oil filter; hand-tighten first, then turn another 1/2~3/4 turn with the chain wrench (avoid over-tightening to prevent sealing ring damage)
- Oil-Air Separator Element
Two types of oil separator elements are available: built-in and external. Confirm the type before replacement.
Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; shorten the cycle under harsh working conditions; replace immediately once the differential pressure transmitter alarms; inspect or replace early if excessive oil consumption is observed
(1) External Oil Separator Element
Replacement steps are identical to the oil filter: unscrew the old separator element with a chain wrench and install the new one.
(2) Built-in Oil Separator Element
Remove all screws around the top cover of the oil tank
Unscrew the bolts of the minimum pressure valve
Disconnect all connected thin pipelines
Pry gently from the side with a flat screwdriver and take out the old oil separator element
Install the new separator element, then reassemble all components in reverse order of disassembly

Replacement Procedures for Two Oils
- Deman Special Compressor Lubricating Oil
Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; check oil level regularly; top up oil if the level falls below the standard mark under rated operating frequency
Operation Steps:
Oil Drain: Unscrew the hex bolt at the end of the ball valve, connect an oil drain hose, and drain all old oil into a dedicated waste oil barrel. After full drainage, jog the main airend for 2~3 seconds to discharge residual oil.
Oil Refill: Unscrew the oil filler cap, pour in new Deman special screw compressor oil until the liquid level reaches the upper red line of the oil sight glass.
Verification: Ensure the running oil level stays between the two red lines on the sight glass during unit operation.
Warning: Never mix lubricants of different brands or models. Only Deman designated special oil can be used; mixing oil may cause coking, carbon buildup, or even main airend seizure.
- Motor Bearing Grease
Service Cycle: Every 4,000 operating hours or 1 year, whichever comes first; adjust the cycle earlier or later based on actual operating conditions
Special Notes:
Sealed motor bearings require no grease refilling
Bearings must be replaced every 20,000 operating hours
Operation Steps:
Unscrew the grease nipple on the motor
Inject new bearing grease with a grease gun
Do not overfill grease, as excessive grease will lead to bearing overheating
Maintenance Cycle Schedule
|
Maintenance Item |
Recommended Cycle |
Key Replacement Notes |
|
Dust Sponge |
4,000 hrs / 1 year |
Blow clean or replace |
|
Air Filter Element |
4,000 hrs / 1 year |
Blow dust from inside out before reuse |
|
Oil Filter |
4,000 hrs / 1 year |
Lubricate sealing ring during installation |
|
Oil-Air Separator Element |
4,000 hrs / 1 year |
Distinguish built-in / external structure |
|
Special Compressor Lubricating Oil |
4,000 hrs / 1 year |
Use designated oil only; no mixing |
|
Motor Bearing Grease |
4,000 hrs / 1 year |
No refilling for sealed bearings; replace bearings at 20,000 hrs |
Safety Reminder: Shut down the unit completely before maintenance, fully release system pressure, disconnect the main power supply, and hang a "Do Not Close Switch" warning sign. After maintenance, verify all parts are correctly installed before trial startup.