Complete Guide to Common Air Compressor Faults
It is inevitable to encounter various faults during the operation of air compressors. This article summarizes and analyzes common air compressor problems in detail.
- High‑Temperature Shutdown
High-temperature shutdown is one of the most frequent air compressor faults. Common causes are listed below:
|
Category |
Specific Faults |
|
Lubricant Issue |
Inferior or degraded lubricating oil |
|
Oil Circuit Issue |
Insufficient lubricant; clogged oil filter or poor oil circulation |
|
Heat Dissipation Issue |
Poor cooler heat exchange, blocked cooling fins; faulty fan motor or contactor failure |
|
Sensor Issue |
Malfunctioning temperature sensor |
|
Valve Issue |
Defective temperature control valve |
|
Air Intake Issue |
Clogged air filter |
|
Airend Issue |
Damaged main airend |
-
Excessive Oil Consumption
Excessive oil consumption is mainly caused by the following factors:
①High Oil Content in Non‑exhaust Air
- Leaking lubrication pipelines or damaged seals
- Damaged cooling oil system
②High Exhaust Oil Content
- Blocked oil return pipe
- Excessively high oil level
- Long-term low-pressure operation
- Failed oil separator core
- Emulsified or deteriorated lubricant
- Failed precision filter
- Frequent loading and unloading cycles
③Oil‑gas Separation Failure
- Damaged oil-gas separation filter element
④Overheating Causing Shutdown
Ambient conditions are key factors leading to overheating:
- Excessive ambient temperature: indoor temperature exceeding the standard limit of 38℃
- Poor ventilation: e.g., air compressors installed too close to boilers, seriously hindering heat dissipation
- Improper installation location: compressors shall be placed in well‑ventilated, low-dust areas to extend service life
Notice: The air compressor is designed for a rated ambient temperature range. If the ambient temperature exceeds the design value, the unit will trigger automatic shutdown protection.
④Mechanical Faults
- Clogged air filter: reduced air intake increases unit load and operating temperature, eventually causing overheating
⑤Oil Separator Malfunction
Low-quality or heavily contaminated lubricant will weaken the oil-air separation efficiency.
> Maintenance Tips
> - Drain oil from the separator if the unit will be idle for a long time
> - Clean separators and heat exchangers with degreasing powder to prevent oil contamination blockage
> - Regularly inspect pipelines for air and oil leakage
> - Perform routine maintenance and replace three filters and lubricants on schedule
⑥Discharge Temperature Lower Than Normal (Below 75℃)
- Excessive cooling water flow
- Prolonged no-load operation
- Excessively low ambient temperature
⑦Too Low Discharge Pressure During Operation
- Malfunctioning intake valve
- Solenoid valve failure
- Leaking relief valve
- Actual air consumption higher than unit output
- Defective pressure sensor
⑧Unit Fails to Start Normally
- Blown fuse
- Faulty starting relay
- Phase loss protection activation
- Motor failure
- Unit internal fault
- Controller malfunction
⑨High Starting Current & Automatic Tripping
- Low input voltage
- Excessively high discharge pressure beyond rated value
- Too short star-delta conversion time (standard: 10–20 seconds)
- Faulty TR time relay
⑩Air end Fails to Run at Full Load
- Three-way solenoid valve failure
- Intelligent controller malfunction
- Unresponsive intake valve
- Proportional valve failure
The above covers ten major types of common air compressor faults and root cause analysis. When abnormalities occur, follow the troubleshooting steps above for inspection. Most minor issues can be quickly located and resolved.