Product Highlight
🌡️ Precise Thermostatic Water Supply
Enjoy complete control with an adjustable water flow and pump rate, enabling you to set and maintain a consistent hot water temperature anywhere from 20°C to 80°C to meet precise application needs.
☁️ Intelligent Cloud-Based Control Management
Utilizing an LED display control panel for clear, stable operation while implementing "Deman Cloud" system to provide real-time monitoring of water usage and system performance, sending immediate alerts for any deviations. This enables swift remote diagnostics and on-site support for maximum uptime and peace of mind.
🛡️ Leakage-free Guarantee
The 316L stainless steel brazed plate heat exchanger, with its 2% molybdenum content, provides enhanced corrosion resistance and stability compared to 304 steel. The heat exchanger of RVC series is covered with a 5-year warranty, while RVB series has a 2-year warranty.
⚡ High Heat Exchange Efficiency
Engineered for seamless integration, the system recovers up to 70% of available waste heat from your air compressor with a remarkable 88% heat exchange efficiency, transforming waste into valuable energy.
♻️ Dual-Source of Energy-saving
The recovery system generates free hot water while also reducing the power consumption of the air compressor's own cooling system, thereby improving the overall energy efficiency of your compressed air station.
Product Structure
High-Efficiency Heat Exchanger
It is capable of recovering up to 70% of waste heat into hot water with a heat exchange efficiency of 88%
Brazed plate type heat exchanger, made of 316L stainless steel, offers superior corrosion resistance
Smart Control System
Deman Cloud monitors water usage in real-time, ensuring efficient operation and sending alerts when necessary
LED display panel provides clear operational information, ensuring ease of use and accurate energy-efficient control of water temperature.
Reliable Electric Control Parts
Uses Schneider contractor and Phoenix switching power supply contact
Bigger electric control cabinet for safer use life
Meticulously Designed Exterior
Carefully engineered with an air compressor-grade chassis, high-quality pipe fittings, precision sheet metal work, and durable industrial painting process, featuring longer service life
Technical Parameter
| Model | RVC22 | RVC37 | RVC55 | RVC75 | RVC110 | RVC160 | RVC200 | RVC250 | RVC300 | RVC500 | RVC630 |
| Power (kW) | 11–22 | 15–37 | 45–55 | 75 | 90–110 | 132–160 | 185–200 | 220–250 | 280–355 | 375–500 | 530–630 |
| Heat Exchange Area (m²) | 1.2 | 1.9 | 2.6 | 3.6 | 5.2 | 7.3 | 11.6 | 15.4 | 25.1 | 34.8 | 43.6 |
| Water / Oil Volume (L) | 1.1 | 1.8 | 2.5 | 3.5 | 5.0 | 7.1 | 15.3 | 20.3 | 31 | 43 | 53.5 |
| Rated Heating Capacity (WJ/h) | 7215 | 120777 | 18031 | 24494 | 35870 | 52221 | 65148 | 81444 | 97808 | 162956 | 205311 |
| Rated Hot Water Output (m³/h, 15℃–60℃) | 0.42 | 0.71 | 1.06 | 1.44 | 2.11 | 3.07 | 3.83 | 4.79 | 5.75 | 9.585 | 12.07 |
| Oil Pipe Connection Size | Rp1" | Rp1 1/2" | Rp2" | DN50 (PN16) | DN65 (PN16) | ||||||
| Water Pipe Connection Size | Rp1" | Rp1 1/2" | Rp1 1/2" (内丝) | DN50 (PN16) | DN65 (PN16) | ||||||
| Dimensions — L (mm) | 500 | 750 | 800 | 910 | 900 | 1050 | 1170 | ||||
| Dimensions — W (mm) | 350 | 400 | 450 | 450 | 650 | 700 | 700 | ||||
| Dimensions — H (mm) | 1300 | 1350 | 1350 | 1500 | 1700 | 1750 | 1750 | ||||
| Warranty | Unit: 2 Years / Heat Exchanger: 5 Years | ||||||||||
Frequently Asked Questions
QWhat temperature range can the RVC series heat recovery system maintain for hot water output?
The RVC series features a precise thermostatic water supply system that allows you to set and maintain hot water temperatures ranging from 20°C to 80°C. The adjustable water flow and pump rate ensure a consistent output tailored to your specific application needs.
QHow much waste heat can the system recover from an air compressor?
The system is engineered to recover up to 70% of available waste heat generated by your air compressor, achieving a remarkable 88% heat exchange efficiency. This transforms otherwise wasted energy into a valuable free source of hot water for your facility.
QWhat material is the heat exchanger made of, and what warranty does it carry?
The heat exchanger uses a 316L stainless steel brazed plate design, which contains 2% molybdenum for superior corrosion resistance and long-term stability compared to standard 304 steel. The RVC series heat exchanger is backed by a 5-year warranty, while the RVB series carries a 2-year warranty.
QHow does the Deman Cloud system work and what are its key benefits?
The Deman Cloud system provides real-time remote monitoring of water usage and overall system performance. It sends immediate alerts whenever deviations are detected, enabling swift remote diagnostics and on-site technical support. Combined with the LED display control panel, operators gain full visibility and control for maximum system uptime.
QHow does the system deliver dual energy savings?
The heat recovery system saves energy in two ways: first, it generates free hot water by capturing compressor waste heat that would otherwise be released into the environment; second, it reduces the power consumption of the air compressor's own cooling system. Together, these improvements significantly boost the overall energy efficiency of your compressed air station.
QWhich air compressor power ranges are compatible with the RVC series models?
The RVC series covers a wide range of compressor capacities, from 11–22 kW (RVC22) up to 530–630 kW (RVC630). With eleven models available, the series is designed to match small, mid-size, and large-scale industrial compressed air systems, making it a versatile heat recovery solution for diverse applications.