Leave Your Message

China Suppliers Factory RVC and RVB Series Heat Recovery System for Efficient Waste Heat Conversion

Deman introduces an innovative solution for energy efficiency in industrial applications with the RVC and RVB Series Waste Heat Recovery System. Designed specifically for China’s manufacturing sector, our system captures and repurposes thermal energy waste from compressed air systems, transforming it into valuable resources like hot water and steam. Crafted from high-quality 316L stainless steel and supported by intelligent Deman Cloud management, this heat recovery system offers exceptional durability, efficiency, and control. As a leading supplier in the industry, our factory is committed to providing advanced technologies that contribute to sustainable energy management and cost savings for businesses in China and beyond

    Product Highlight

    Precise Thermostatic Water Supply

    Enjoy complete control with an adjustable water flow and pump rate, enabling you to set and maintain a consistent hot water temperature anywhere from 20°C to 80°C to meet precise application needs.

    Intelligent Cloud-Based Control Management

    Utilizing an LED display control panel for clear, stable operation while implementing "Deman Cloud" system to provide real-time monitoring of water usage and system performance, sending immediate alerts for any deviations. This enables swift remote diagnostics and on-site support for maximum uptime and peace of mind.

    Leakage-free Guarantee

    The 316L stainless steel brazed plate heat exchanger, with its 2% molybdenum content, provides enhanced corrosion resistance and stability compared to 304 steel. The heat exchanger of RVC series is covered with a 5-year warranty, while RVB series has a 2-year warranty.

    High Heat Exchange Efficiency

    Engineered for seamless integration, the system recovers up to 70% of available waste heat from your air compressor with a remarkable 88% heat exchange efficiency, transforming waste into valuable energy.

    Dual-Source of Energy-saving

    The recovery system generates free hot water while also reducing the power consumption of the air compressor's own cooling system, thereby improving the overall energy efficiency of your compressed air station.

    Product Structure

    High-Efficiency Heat Exchanger

    High-Efficiency Heat Exchanger

    • It is capable of recovering up to 70% of waste heat into hot water with a heat exchange efficiency of 88%
    • Brazed plate type heat exchanger, made of 316L stainless steel, offers superior corrosion resistance

    Smart Control System

    • Deman Cloud monitors water usage in real-time, ensuring efficient operation and sending alerts when necessary
    • LED display panel provides clear operational information, ensuring ease of use and accurate energy-efficient control of water temperature.
    Smart Control System
    Reliable Electric Control Parts

    Reliable Electric Control Parts

    • Uses Schneider contractor and Phoenix switching power supply contact
    • Bigger electric control cabinet for safer use life

    Meticulously Designed Exterior

    • Carefully engineered with an air compressor-grade chassis, high-quality pipe fittings, precision sheet metal work, and durable industrial painting process, featuring longer service life
    Meticulously Designed Exterior

    Technical Parameter

    Model RVC22 RVC37 RVC55 RVC75 RVC110 RVC160 RVC200 RVC250 RVC300 RVC500 RVC630
    Power (kW) 11–22 15–37 45–55 75 90–110 132–160 185–200 220–250 280–355 375–500 530–630
    Heat Exchange Area (m²) 1.2 1.9 2.6 3.6 5.2 7.3 11.6 15.4 25.1 34.8 43.6
    Water / Oil Volume (L) 1.1 1.8 2.5 3.5 5.0 7.1 15.3 20.3 31 43 53.5
    Rated Heating Capacity (WJ/h) 7215 120777 18031 24494 35870 52221 65148 81444 97808 162956 205311
    Rated Hot Water Output (m³/h, 15℃–60℃) 0.42 0.71 1.06 1.44 2.11 3.07 3.83 4.79 5.75 9.585 12.07
    Oil Pipe Connection Size Rp1" Rp1 1/2" Rp2" DN50 (PN16) DN65 (PN16)
    Water Pipe Connection Size Rp1" Rp1 1/2" Rp1 1/2" (内丝) DN50 (PN16) DN65 (PN16)
    Dimensions – L (mm) 500 750 800 910 900 1050 1170
    Dimensions – W (mm) 350 400 450 450 650 700 700
    Dimensions – H (mm) 1300 1350 1350 1500 1700 1750 1750
    Warranty Unit: 2 Years  /  Heat Exchanger: 5 Years

    Frequently Asked Questions

    Q What temperature range can the RVC series waste heat recovery system provide for hot water output?
    The RVC series supports an adjustable hot water temperature range from 20°C to 80°C. The precise thermostatic control allows users to set and maintain their desired temperature consistently, making it suitable for a wide variety of industrial and commercial hot water applications.
    Q How much waste heat can the system recover from an air compressor?
    The system is engineered to recover up to 70% of the available waste heat generated by your air compressor, with a heat exchange efficiency of 88%. This transforms energy that would otherwise be wasted into valuable hot water, significantly reducing operational costs.
    Q What material is the heat exchanger made of, and what warranty does it carry?
    The heat exchanger is a brazed plate type made from 316L stainless steel, which contains 2% molybdenum for superior corrosion resistance compared to standard 304 steel. The RVC series heat exchanger is backed by a 5-year warranty, while the RVB series carries a 2-year warranty. The complete unit itself comes with a 2-year warranty.
    Q How does the Deman Cloud system help with system management and maintenance?
    The Deman Cloud system provides real-time monitoring of water usage and overall system performance. It sends immediate alerts whenever deviations or anomalies are detected, enabling swift remote diagnostics and timely on-site support. This intelligent cloud-based management minimizes downtime and ensures continuous, efficient operation.
    Q Which air compressor power ranges are compatible with the RVC series models?
    The RVC series covers a broad range of air compressor capacities, from 11–22 kW (RVC22) up to 530–630 kW (RVC630). With eleven models available, the series accommodates small to large-scale compressed air stations, ensuring there is a suitable model for virtually any industrial requirement.
    Q Does the waste heat recovery system affect the air compressor's own energy consumption?
    Yes, in addition to generating free hot water, the waste heat recovery system also reduces the power consumption of the air compressor's own cooling system. This dual energy-saving effect improves the overall energy efficiency of the entire compressed air station, lowering utility costs and reducing the carbon footprint of your operations.