Leave Your Message

China RVC and RVB Series Heat Recovery Systems - Top Suppliers and Factory for Energy Efficiency Solutions

,

Deman, a leading China supplier, is revolutionizing energy efficiency with our advanced heat recovery technology: the RVC and RVB Series Waste Heat Recovery System. This innovative system captures and repurposes thermal energy waste from your compressed air systems, converting it into valuable resources such as hot water and hot steam. Crafted with high-quality 316L stainless steel and equipped with the intelligent Deman Cloud management system, our products ensure unmatched efficiency, exceptional durability, and superior control. Trust Deman, your reliable factory partner in energy-saving solutions.

,

    Product Highlight

    Precise Thermostatic Water Supply

    Enjoy complete control with an adjustable water flow and pump rate, enabling you to set and maintain a consistent hot water temperature anywhere from 20°C to 80°C to meet precise application needs.

    Intelligent Cloud-Based Control Management

    Utilizing an LED display control panel for clear, stable operation while implementing "Deman Cloud" system to provide real-time monitoring of water usage and system performance, sending immediate alerts for any deviations. This enables swift remote diagnostics and on-site support for maximum uptime and peace of mind.

    Leakage-free Guarantee

    The 316L stainless steel brazed plate heat exchanger, with its 2% molybdenum content, provides enhanced corrosion resistance and stability compared to 304 steel. The heat exchanger of RVC series is covered with a 5-year warranty, while RVB series has a 2-year warranty.

    High Heat Exchange Efficiency

    Engineered for seamless integration, the system recovers up to 70% of available waste heat from your air compressor with a remarkable 88% heat exchange efficiency, transforming waste into valuable energy.

    Dual-Source of Energy-saving

    The recovery system generates free hot water while also reducing the power consumption of the air compressor's own cooling system, thereby improving the overall energy efficiency of your compressed air station.

    Product Structure

    High-Efficiency Heat Exchanger

    High-Efficiency Heat Exchanger

    • It is capable of recovering up to 70% of waste heat into hot water with a heat exchange efficiency of 88%
    • Brazed plate type heat exchanger, made of 316L stainless steel, offers superior corrosion resistance

    Smart Control System

    • Deman Cloud monitors water usage in real-time, ensuring efficient operation and sending alerts when necessary
    • LED display panel provides clear operational information, ensuring ease of use and accurate energy-efficient control of water temperature
    Smart Control System
    Reliable Electric Control Parts

    Reliable Electric Control Parts

    • Uses Schneider contractor and Phoenix switching power supply contact
    • Bigger electric control cabinet for safer use life

    Meticulously Designed Exterior

    • Carefully engineered with an air compressor-grade chassis, high-quality pipe fittings, precision sheet metal work, and durable industrial painting process, featuring longer service life
    Meticulously Designed Exterior

    Technical Parameter

    Model RVC22 RVC37 RVC55 RVC75 RVC110 RVC160 RVC200 RVC250 RVC300 RVC500 RVC630
    Power (kW) 11–22 15–37 45–55 75 90–110 132–160 185–200 220–250 280–355 375–500 530–630
    Heat Exchange Area (m²) 1.2 1.9 2.6 3.6 5.2 7.3 11.6 15.4 25.1 34.8 43.6
    Water/ Oil Volume (L) 1.1 1.8 2.5 3.5 5.0 7.1 15.3 20.3 31 43 53.5
    Rated Heating Capacity (WJ/h) 7215 120777 18031 24494 35870 52221 65148 81444 97808 162956 205311
    Rated Hot Water Output (m³/h, 15℃–60℃) 0.42 0.71 1.06 1.44 2.11 3.07 3.83 4.79 5.75 9.585 12.07
    Oil Pipe Connection Size Rp1" Rp1 1/2" Rp2" DN50(PN16) DN65(PN16)
    Water Pipe Connection Size Rp1" Rp1 1/2" Rp1 1/2"(内丝) DN50(PN16) DN65(PN16)
    Dimensions-L(mm) 500 750 800 910 900 1050 1170
    Dimensions-W(mm) 350 400 450 450 650 700 700
    Dimensions-H(mm) 1300 1350 1350 1500 1700 1750 1750
    Warranty Unit: 2 Years / Heat Exchanger: 5 Years

    Frequently Asked Questions

    What temperature range can the RVC series waste heat recovery system maintain for hot water output?

    The RVC series waste heat recovery system provides precise thermostatic control, allowing users to set and maintain a consistent hot water temperature ranging from 20°C to 80°C. This wide range makes it suitable for a variety of industrial and commercial hot water applications.

    How much waste heat can the system recover from an air compressor?

    The system is engineered to recover up to 70% of available waste heat generated by your air compressor, achieving an impressive 88% heat exchange efficiency. This transforms energy that would otherwise be wasted into valuable, usable hot water for your facility.

    What material is the heat exchanger made of, and what warranty does it come with?

    The heat exchanger is a brazed plate type manufactured from 316L stainless steel, which contains 2% molybdenum for superior corrosion resistance and long-term durability compared to standard 304 stainless steel. The RVC series heat exchanger is backed by a 5-year warranty, while the RVB series carries a 2-year warranty. The overall unit comes with a 2-year warranty.

    How does the Deman Cloud system help with system management and maintenance?

    The Deman Cloud system provides real-time remote monitoring of water usage and overall system performance. It automatically sends immediate alerts whenever deviations or abnormalities are detected, enabling swift remote diagnostics and timely on-site support. This minimizes downtime and ensures the system operates at peak efficiency at all times.

    What compressor power ranges are compatible with the RVC series models?

    The RVC series covers a broad range of air compressor power ratings, from 11 kW (RVC22) up to 630 kW (RVC630). Whether you operate a small workshop or a large industrial compressed air station, there is an RVC model designed to match your specific compressor capacity and hot water demand.

    Does the waste heat recovery system affect the performance of the air compressor?

    No — in fact, it improves it. By recovering waste heat through the heat exchanger, the system simultaneously reduces the load on the air compressor's own cooling system. This dual energy-saving effect lowers the compressor's power consumption and improves the overall energy efficiency of your entire compressed air station, resulting in reduced operating costs.