| 1. Bulk Water Separator |
Removes condensed liquid water and larger droplets from compressed air. |
Designed for bulk liquid removal; not usually specified by a fine-particle micron rating. |
Approximately 0.02–0.08 bar at the rated flow |
Upstream of coalescing filters, dryers, and distribution headers. |
Check flow capacity, drain type, pressure rating, and whether the unit is designed for the expected condensate load. |
| 2. General-Purpose Particulate Filter |
Captures solid particles such as rust, scale, and pipe debris. |
Commonly around 3–5 μm, depending on filter design. |
Approximately 0.03–0.10 bar at the rated flow |
General plant air and protection of downstream equipment. |
Match the stated particle rating to the process requirement; consider element capacity and differential-pressure monitoring. |
| 3. Coalescing Prefilter |
Collects fine liquid oil and water aerosols and traps fine particulates. |
Often rated near 1 μm for particles; aerosol performance varies by element. |
Approximately 0.05–0.12 bar at the rated flow |
Upstream of a fine coalescing filter or refrigerated dryer. |
Confirm aerosol-removal performance, condensate drainage, and compatibility with the compressor lubricant. |
| 4. Fine Coalescing Filter |
Reduces very fine oil and water aerosols and fine solid contaminants. |
Often specified near 0.01 μm for aerosols; verify the manufacturer’s test method and rated performance. |
Approximately 0.08–0.20 bar at the rated flow |
Applications requiring low aerosol carryover, including instrument and process air systems. |
Review residual-oil data, flow at operating pressure, element life, and the need for an upstream prefilter. |
| 5. Activated-Carbon Adsorption Filter |
Adsorbs oil vapors and some hydrocarbon odors; it does not remove bulk liquid or all particles by itself. |
Vapor-removal performance is application- and media-dependent; no single micron rating applies. |
Approximately 0.05–0.15 bar at the rated flow |
Point-of-use treatment where reduced oil-vapor or odor levels are required. |
Use after suitable coalescing filtration; check vapor capacity, humidity sensitivity, service life, and breakthrough monitoring needs. |
| 6. Fine Particulate Afterfilter |
Captures desiccant dust and other fine solids downstream of a dryer or adsorber. |
Commonly around 1 μm; finer grades are available. |
Approximately 0.04–0.12 bar at the rated flow |
After desiccant dryers and before sensitive pneumatic or process equipment. |
Check particle rating, dust-holding capacity, flow direction, and compatibility with the downstream air-quality target. |
| 7. High-Temperature Compressed-Air Filter |
Filters hot compressed air where standard element materials may not be suitable. |
Available in particulate or coalescing grades; rating depends on the selected element. |
Typically 0.05–0.20 bar at the rated flow |
Installations with elevated air temperature or limited cooling before treatment. |
Verify maximum continuous temperature, seal and element materials, operating pressure, and the temperature used for the flow rating. |
| 8. High-Flow Filter Housing |
Provides filtration at high air demand while limiting velocity and pressure loss. |
Available in several particulate and coalescing grades. |
Approximately 0.03–0.15 bar when correctly sized |
Large compressor rooms, main headers, and systems with high or variable demand. |
Size for actual flow at operating pressure; account for peak demand, connection size, element area, and future capacity. |
| 9. Duplex Changeover Filter Assembly |
Allows one filter chamber to remain in service while the other is isolated for element replacement. |
Depends on the installed element; particulate and coalescing grades are common. |
Depends on element and flow; confirm pressure loss through the complete assembly. |
Continuous-operation systems where filter servicing must not interrupt air supply. |
Check changeover-valve design, isolation and venting provisions, pressure rating, and whether both housings can handle the required flow. |
| 10. Sterile-Grade Point-of-Use Filter |
Provides fine particulate and microbial retention in appropriately designed and validated systems. |
Often uses a 0.2 μm-rated membrane; retention claims depend on filter validation and application. |
Varies by membrane area and flow; use the element’s rated-flow data. |
Selected food, beverage, pharmaceutical, and other hygienic process-air applications. |
Confirm the required validation, sterilization method, housing hygiene, integrity-testing procedure, and applicable industry requirements. |